| PRODUCTS > HTI-GESAB |
 |
Profile
More than 35 years HTI-GESAB Hoch-Temperatur Industrieanlagen GmbH is successfully manufacturing and delivering Thermal Oil-Heater plants for ship building and industry.
In 1967 HTI Hoch-Temperatur Industrieanlagen, has been established as a single company. In 1971 the company grew from engineering office - headquarter Hamburg - to a production plant in Ellerau before the gates of Hamburg. In 1981 HTI changed into GmbH (private limited company - plc).
In July 2001 the enterprise cooperate with the License partner Gesab Göteborgs Energy Systems AB and created HTI-GESAB Hoch- Temperatur Industrieanlagen GmbH as a new society.
Today HTI-GESAB Hoch- Temperatur Industrieanlagen GmbH are a highly motivated team with headquarter in Germany, as well as a agencies in Sweden and China.
In Ellerau is the manufacturing of heater up to a single weight of 25 t with a cacity of max. 10.000 kW and on inquiry bigger than that.
Up to now, HTI-GESAB Hoch- Temperatur Industrieanlagen GmbH has deliver more than 700 heater plants for marine operating and more than 600 land plants, which distinguishes our cometence and our know-how in this area.
The traffic-favourable location of the HTI GESAB Hoch- Temperatur Industrieanlagen GmbH to the BAB A7 and to the airport Hamburg ensures a fast and reliable service.
Field of possibilities for thermal oil plants
General:
Thermal oil plants on the basis of mineral heat carrier oils or synthetic heat carriers can be employed in industrial, technological heat processes which require temperatures between 120 °C and 400 °C.
Advantages:
The advantages of thermal oil plants, contrary to steam plants, are:
• plants work almost unpressurised or plants with synthetic heat carriers work with low steam pressure respectively
• maintenance of heat carrier similar to water processing for steam boiler plants, is not needed
• corrosion of boiler plants, pipe line systems, heat exchangers in consumer and at armatures is excluded, due to the anti-corrosion characteristics of heat carrier oil
• possibilities of heating as well as cooling with same heat carrier if an adequate plant unit is available
• due to qualities of heat carrier it is guaranteed that even with erections out of doors and temperatures below zero, no freezing of heat carrier will occur.
Products:
Thermal Oil Heaters
Auxiliary Heater Type HE
Exhaust Gas Heat Exchanger Type AHE
Thermal Oil Heating Systems
www.hti-ellerau.de
|
WHY THERMAL OIL
There are two different media to use for practical heating applications:
THERMAL OIL and STEAM/HOT WATER
|
This table illustrates the differences |
PROCESS |
HEATING MEDIA |
|
THERMAL OIL |
STEAM / HOT WATER |
Corrosion inside heating pipes |
NO |
YES |
Corrosion outside pipes in the Exhaust Heater depending of low incoming temperature |
NO |
YES |
Cooling system for condensate |
NO |
YES
(Continuously) |
Water treatment plant |
NO |
YES
(Continuously) |
Working temperature |
140 - 350ºC |
140 - 350ºC |
Working pressure |
Low pressure
6 - 7 Bar
(only circulating pump) |
180ºC - 10 Bar
250ºC - 40 Bar
350ºC - 90 Bar
(High pressure system) |
Risk for damages during freezing |
NO |
YES
(Large risk) |
Maintenance cost |
LOW
(Very limited) |
LARGER
(Large and Continuous) |
Condensate cooler |
NO |
YES |
Number of Armature |
Less |
More |
Leakage Risk |
NO
(Welded pipes) |
YES
(Flanges and sealings) |
Energy saving |
YES
(Compared to Steam system) |
NO |
|
| |
|
|
|